土壤容重和温度对时域反射仪测定土壤水分的影响
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

*国家自然科学基金(批准号:49391600)


A LABORATORY EXPERIMENT OF TIME DOMAIN REFLECTOMETRY FOR SOIL WATER MEASUREMENT INCLUDING EFFECTS OF BULK DENSITY AND TEMPERATURE
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    土壤含水量(θv)与电磁波在插入土壤的时域反射仪(TDR)探针中传播时间(T)的半理论、半经验标定曲线θv=(T/Ta-Ts/Ta)/(Kw0.5-1)通常用于计算土壤含水量.本项试验应用TDR测定了不同质地及不同容重条件下烘干土壤的Ts/Ta值.结果表明,四种被测土壤的Ts/Ta值介于1.61~1.80,且土壤容重大,Ts/Ta值也大,三种农业土壤的Ts/Ta平均值可取1.68.用烘干至饱和含水量的砂质壤土和壤上的土柱试验结果表明,选用不同的Ts/Ta值,引起的含水量偏差分别为0.001~-0.005cm3/cm3和0.007~0.006cm3/cm3.对于砂质壤土,在实际合水量不变但改变土壤温度的情况下,TDR测定的含水量在实际含水量大于0.30cm3/cm3时有明显的偏差,且温度升高,TDR测定的含水量偏低,反之亦然.本文还给出了温度每增加(或减少)1℃引起的含水量测定值的偏差范围以及进行修正的方法.

    Abstract:

    The semi-theoretical and empirical calibration curve,θv=(T/Ta-Ts/Ta)/(Kw0.5-1),soil water content(θv) versus propagation time(T)of electromagnetic wave along TDR probe inserted in soil,is used to calculate soil water content.In this experiment TDR is used to measure Ts/Ta value of oven-dried soils with different texture and bulk density.The result showed that Ts/Ta value from 1.61 to 1.80 for four soils,and the larger bulk density,the larger Ts/Ta value.For three agricultural soils the average Ts/Ta can be used as 1.68.The column experiments on sandy loam and loam showed(water content from oven-dry to saturation) that different Ts/Ta values lead to water content deviation 0.001~-0.005 cm3 /cm3 and 0.007~-0.006cm3/cm3 respectively.For sandy loam with varied soil temperature,water content measured by TDR deviated from real values when it is higher than 0.30 cm3/cm3.The higher temperature,the lower water content measured.This paper also indicates the deviation range of measured water content with temperature increasing(or decreasing) 1℃ and its modification method.

    参考文献
    相似文献
    引证文献
引用本文

龚元石,曹巧红,黄满湘.土壤容重和温度对时域反射仪测定土壤水分的影响[J].土壤学报,1999,36(2):145-153. DOI:10.11766/trxb199805080201 Gong Yuan-shi, Cao Qiao-hong, Huang Man-xiang. A LABORATORY EXPERIMENT OF TIME DOMAIN REFLECTOMETRY FOR SOIL WATER MEASUREMENT INCLUDING EFFECTS OF BULK DENSITY AND TEMPERATURE[J]. Acta Pedologica Sinica,1999,36(2):145-153.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:1998-05-08
  • 最后修改日期:1998-10-30
  • 录用日期:
  • 在线发布日期: 2013-02-25
  • 出版日期: