三种pH电极长期原位监测土壤酸碱度的稳定性
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

中国科学院战略性先导科技专项(XDA0440404)和国家重点农业科技项目(NK2022180104)资助 Supported by the Strategic PriorityResearch Program of the Chinese Academy of Sciences (No.XDA0440404), and the National Key Agricultural Science and Technology Projectof China(No.NK2022180104)


Stability Assessment of Three pH Electrode Types for In-situ Long-term Soil Acidity/Alkalinity Monitoring
Author:
Affiliation:

Fund Project:

Supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (XDA0440404), and the National Key Agricultural Science and Technology Project of China (NK2022180104)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    及时准确地获取原位土壤pH对指导农业生产和管控土壤污染具有重要意义,但pH电极在长期土壤监测过程中的稳定性尚不明确。本研究选择了三种pH电极(球泡玻璃电极、锥形玻璃pH复合电极和锑(Sb)金属pH电极),将pH敏感部位埋入酸性红壤中,进行了为期350天的土壤pH原位监测,同时使用额外的锥形玻璃pH复合电极进行原位pH测定。结果表明,3种电极在埋入土壤前后的电极斜率变化较小,球泡和锥形玻璃电极、Sb金属pH电极的斜率分别为-60.30~-58.07、-55.65~-50.79和-35.24 ~-34.38mV/pH,其中球泡玻璃电极的灵敏度最高。与额外的锥形玻璃电极原位测定得到的土壤pH进行相关性分析结果表明,球泡玻璃电极和Sb金属pH电极原位监测与测定得到的pH之间存在极显著相关(P<0.01),相关系数r分别为0.74、0.75、0.56和0.80,而锥形玻璃电极两种方法获得的pH之间没有相关性,r分别为-0.38和0.15(P>0.05)。因此,球泡玻璃电极和Sb金属pH电极均可用于土壤pH的长期监测,带有保护装置的球泡玻璃电极适用于短期精确的土壤pH原位监测,而Sb金属电极则更适合长期原位监测。

    Abstract:

    【Objective】 Timely and accurate measurement of in situ soil pH is crucial for agricultural production and soil pollution remediation. However, the long-term stability of pH electrodes in soil monitoring remains a challenge. 【Method】 This study evaluated the effectiveness of three types of pH electrodes: spherical glass combined pH electrodes, conical glass combined pH electrodes, and an antimony (Sb) metal pH electrode, for monitoring the pH of acidic Ultisol over 350 days. Additionally, in situ soil pH values from incubated soil were measured using an extra conical glass combined pH electrode. 【Result】 The slopes of all three electrode types showed minimal changes before and after embedding in soil. The slope ranges for the spherical glass, conical glass, and Sb metal electrodes were –58.07 to –60.30, –50.79 to –55.65, and -34.38 to –35.24 mV/pH, respectively, with the spherical glass electrode showing the highest sensitivity. Correlation analysis between in situ monitored pH values and those measured with the extra conical glass electrode revealed significant correlations for the spherical glass and Sb metal electrodes (P<0.01), with correlation coefficients (r) of 0.74, 0.75, 0.56, and 0.80, respectively. In contrast, no significant correlation was observed between the pH values measured by the conical glass electrode and the extra electrode, with r values of –0.38 and 0.15, respectively (P>0.05). 【Conclusion】 These findings suggest that both the spherical glass and Sb metal electrodes are suitable for long-term soil pH monitoring. However, the spherical glass electrode with a protective device is recommended for short-term, high-accuracy monitoring, while the Sb metal electrode is more suited for long-term monitoring applications.

    参考文献
    相似文献
    引证文献
引用本文

张雪晴,张凤,冯天华,李科伟,洪志能,时仁勇,施杨潇潇,姜军,徐仁扣.三种pH电极长期原位监测土壤酸碱度的稳定性[J].土壤学报,2025,62(6):1680-1688. DOI:10.11766/trxb202412090478 ZHANG Xueqing, ZHANG Feng, FENG Tianhua, LI Kewei, HONG Zhineng, SHI Renyong, SHI Yangxiaoxiao, JIANG Jun, XU Renkou. Stability Assessment of Three pH Electrode Types for In-situ Long-term Soil Acidity/Alkalinity Monitoring[J]. Acta Pedologica Sinica,2025,62(6):1680-1688.